RBRsolo⁴ x, RBRduet⁴ D.x: exchangeable loggers
The RBR exchangeable instruments can integrate a selection of RBR serial sensors, such as dissolved oxygen, turbidity, and chlorophyll-a. Low power consumption, infinite memory, and ability to endure harsh conditions make the RBRsolo4 x |2x and RBRduet4 D.x |2x instruments a perfect choice for many oceanographic applications.
- Infinite memory*
- Swap any RBR sensor ‘on the go’
- Any AA battery chemistry
- Standard sampling up to 2Hz, and optionally up to 32Hz
- USB-C download
- Optional fast sampling, tide & wave
*not really, but we stopped counting at billions of samples
- Available sensors:
- RBRcoda Tu
- RBRcoda chl-a
- RBRcoda T.ODO
- RBRcoda³ T
- RBRcoda³ D
- RBRquadrante
Features & Configurations
*not really, but we stopped counting at billions
The RBRsolo4 x |2x and RBRduet4 D.x |2x are compact, lightweight exchangeable loggers designed for high-precision oceanographic measurements in demanding environments. It combines exceptional accuracy and resolution using any standard AA battery chemistry. Engineered for durability in harsh marine conditions, these instruments delivers reliable, long-term performance across a wide range of oceanographic applications.
Infinite storage capacity and reliable battery power facilitate long deployments with higher sampling rates. Downloads are quick with USB-C.
A dedicated holder makes it simple to replace desiccant before each deployment.
The calibration coefficients are stored with the instrument, and only one software tool, Ruskin, is required to operate it. Datasets can be read directly in Matlab, or exported to Excel, OceanDataView®, or text files.
Optional Configurations
| | fast | up to 32Hz sampling |
|---|---|
| | deep | up to 10000m |
Specifications
| Storage | Infinite memoryFootnote * |
|---|---|
| Power | Any 2x AA cell |
| Communication | USB-C |
| Clock drift | ±60 seconds/year |
| Housing | Plastic or titanium |
| Depth rating | Up to 1700m (plastic), up to 10000m (Ti) |
| Diameter | ~25mm |
| LengthFootnote |
~305mm to 349mm (pl) ~319mm to 358mm (Ti) |
| WeightFootnote |
<219g in air, <40g in water (plastic) |
| <520g in air, <340g in water (Ti) |
*not really, but we stopped counting at billions of samples.
| Calibrated rangeFootnote* | -5°C to 35°C |
|---|---|
| Initial accuracy | ±0.002°C |
| Resolution | <0.00005°C |
| Typical stability | ±0.002°C/year |
| Time constant | <1s standard, <0.1s |fast |
*A wider temperature range is available on request. Contact RBR for more information.
| Calibrated rangeFootnote 1 | 20 / 50 / 100 / 200 / 500 / 1000dbar (plastic) |
|---|---|
| 2000 / 6000 / 10000dbar (Ti) | |
| Initial accuracyFootnote 2 | ±0.05% full scale |
| Resolution | <0.001% full scale |
| Typical Stability | ±0.05% full scale / year |
| Time constant | <10ms |
1Recommended depth for wave measurements is less than 50m.
2±0.01% full scale is available upon request. Contact RBR for more information.
| Wavelength | 880nm |
|---|---|
| Centroid angle | 90° |
| Linearity, R | 0.99 |
| Initial accuracy | 5% |
| Calibrated range | 0 – 1000FTU |
| Measurement rangeFootnote * | 0 – 1500FTU |
*Response becomes non-linear above 1000FTU.
| Wavelength | 880nm |
|---|---|
| Centroid angle | 135° |
| Linearity, R² | 0.99 |
| Initial accuracy | 5% |
| Calibrated range | 1000-4000FTU |
| Measurement rangeFootnote* | 0 – 20000FTU |
| Detection limit | 2.0FTU |
* Response becomes non-linear below 500FTU and above 15000FTU.
| Wavelength | 470nm/695nm (excitation/emission) |
|---|---|
| Calibrated rangeFootnote* | 0-50µg/L |
| Measurement range | 0-500µg/L |
| Detection limit | 0.02µg/L |
* Scaled for the in vivo fluorescence response.
| Linearity, R | 0.99 |
|---|---|
| Initial accuracy | 5% |
| Calibrated range | 0-500μM concentration 0 – 120% saturation 1.5°C to 30°C temperature |
|---|---|
| Initial accuracy | Maximum of ±8μmol/L or ±5% | fast Maximum of ±2μmol/L or ±1.5% standard Maximum of ±2μmol/L or ±1.5% | slow |
| Resolution | <1µmol/L (saturation 0.4%) | fast <0.5μmol/L (saturation 0.2%) standard <0.1μmol/L (saturation 0.04%) | slow |
| Time constant | <1s | fast, <8s standard, <30s | slow |
| Sampling rates | 24hr to 1Hz |
Output values
- Temperature (°C)
- Dissolved O2 concentration (μmol/L)
- Dissolved O2 concentration (salinity compensated, μmol/L)
- Dissolved O2 saturation (%)
- Dissolved O2 phase (°)