RBRduet⁴ dual sensor logger

Our most compact, lightweight, and versatile dual channel logger.

  • Infinite memory*
  • Any AA battery chemistry
  • Standard sampling up to 2Hz, and optionally up to 32Hz
  • USB-C download
  • Optional fast sampling, tide, and wave

*not really, but we stopped counting at billions.

  • T.Dtemperature, pressure
  • D.Tu |2xpressure, turbidity
  • D.chl-a |2xpressure, chlorophyll-a
  • D.ODO |2xpressure, temperature, optical dissolved oxygen

Features & Configurations

long deployments

compact and lightweight

Two aa batteries

UP TO 32Hz SAMPLING

USB-C download

Infinite memory*

*not really, but we stopped counting at billions

RBRduet4 loggers are compact, lightweight instruments designed for high-precision oceanographic measurements in demanding environments. They combine exceptional accuracy and resolution using any standard AA battery chemistry.

Engineered for durability in harsh marine conditions, the RBRduet4 delivers reliable, long-term performance across a wide range of oceanographic applications.

Optional Configurations

| fast32 up to 32Hz continuous sampling
| tide32 continuous sampling or tidal averaging
| wave32 continuous sampling, tidal averaging, or wave burst
| deep depths up to 10000m
| 2x double the power of RBRduet4 T.D

Specifications

Physical
Power Any AA cell(s)
Communication USB-C
Storage Infinite memory*
Clock drift ±60 seconds/year
Depth rating up to 1700m (plastic), up to 10000 (Ti)
Diameter ~25mm
Length Varies per sensor
Weight (air) Varies per sensor
Weight (water) Varies per sensor

*Not really, but we stopped counting at billions.

Temperature
Calibrated rangeFootnote* -5°C to 35°C
Initial accuracy ±0.002°C
Resolution <0.00005°C
Typical stability ±0.002°C/year
Time constant <1s standard, <0.1s |fast

*A wider temperature range is available on request. Contact RBR for more information.

Pressure
Calibrated rangeFootnote 1 20 / 50 / 100 / 200 / 500 / 1000dbar (plastic)
  2000 / 6000 / 10000dbar (Ti)
Initial accuracyFootnote 2 ±0.05% full scale
Resolution <0.001% full scale
Typical Stability ±0.05% full scale / year
Time constant <10ms

1Recommended depth for wave measurements is less than 50m.

2±0.01% full scale is available upon request. Contact RBR for more information.

Turbidity
Wavelength 880nm
Centroid angle 90°
Linearity, R 0.99
Initial accuracy 5%
Calibrated range 0 – 1000FTU
Measurement rangeFootnote * 0 – 1500FTU

*Response becomes non-linear above 1000FTU.

Turbidity (optical backscatter)
Wavelength 880nm
Centroid angle 135°
Linearity, R² 0.99
Initial accuracy 5%
Calibrated range 1000-4000FTU
Measurement rangeFootnote* 0 – 20000FTU
Detection limit 2.0FTU

* Response becomes non-linear below 500FTU and above 15000FTU.

Chlorophyll-a
Wavelength 470nm/695nm (excitation/emission)
Calibrated rangeFootnote* 0-50µg/L
Measurement range 0-500µg/L
Detection limit 0.02µg/L

* Scaled for the in vivo fluorescence response.

Optical
Linearity, R 0.99
Initial accuracy 5%


Oxygen
Calibrated range 0-500μM concentration
0 – 120% saturation
1.5°C to 30°C temperature
Initial accuracy Maximum of ±8μmol/L or ±5% | fast
Maximum of ±2μmol/L or ±1.5% standard
Maximum of ±2μmol/L or ±1.5% | slow
Resolution <1µmol/L (saturation 0.4%) | fast
<0.5μmol/L (saturation 0.2%) standard
<0.1μmol/L (saturation 0.04%) | slow
Time constant <1s | fast, <8s standard, <30s | slow
Sampling rates 24hr to 1Hz


Output values

  • Temperature (°C)
  • Dissolved O2 concentration (μmol/L)
  • Dissolved O2 concentration (salinity compensated, μmol/L)
  • Dissolved O2 saturation (%)
  • Dissolved O2 phase (°)

Ready to dive in? Contact us today.

We partner with passionate oceanography and water quality experts worldwide to ensure you receive excellent local customer service, sales, and support.
Get started