compact and lightweight
RBRduetยณ T.D: dual-channel compact logger
Our most compact, lightweight, and versatile dual-channel logger.
- Long deployments
- Compact and lightweight
- Any AA battery
- Standard sampling up to 2Hz, optionally up to 32Hz
- USB-C download
- Optional |โtide and |โwave configurations available
- Optional |โdeep variant available
- Cabledย ย RBRcoda3ย T.Dย ย variant available
See also: Compact | Tide & Wave and Standard | Tide & Wave

Features & Configurations
The RBRduet3ย T.Dย provides accurate temperature and pressure measurements during long deployments. Low power consumption, large memory, and ability to endure harsh conditions make it a perfect instrument for many oceanographic applications, including tide levels and wave characteristics.
The RBRduetยณ T.D is calibrated to an accuracy of ยฑ0.002ยบC (ITS-90 and NIST traceable standards) and and accuracy of 0.05% full scale for pressure (between -5ยบC and 35ยบC). The standard thermistor has a time constant of approximately one second.
The RBRduetยณ T.D has a measurement range of -5ยบC to +35ยบC in its standard calibration. However, it can be calibrated from -40ยบC to +50ยบC. Contact RBR about your particular measurement range. There are a number of pressure rating options from 20dbar to 10000dbar.
Optional Configurations
RBRduetยณ T.D | temperature and pressure; up to 2Hz continuous sampling, depths up to 1000m |
---|---|
RBRduetยณ T.Dโ|โfast | temperature and pressure; up to 8Hz, 16Hz, or 32Hz continuous sampling |
RBRduetยณ T.Dโ|โtide16 | temperature and pressure; continuous sampling or tidal averaging |
RBRduetยณ T.D | wave16 | temperature and pressure; continuous sampling, tidal averaging, or wave burst |
RBRduetยณ T.D | deep | temperature and pressure; depths up to 10000m |
Specifications
Storage | ~45 million samples* *A sample may include multiple readings. |
---|---|
Power | Any AA cell |
Communication | USB-C |
Clock drift | ยฑ60 seconds/year |
Depth rating |
Up to 1000m (plastic) |
Diameter | ~25mm |
Length | ~266mm |
Weight (air) | 150g in air, 30g in water (plastic) 350g in air, 240g in water (Ti) |
Calibrated range* | -5ยฐC to 35ยฐC * A wider temperature range is available upon request. Contact RBR for more information. |
---|---|
Initial accuracy | ยฑ0.002ยฐC |
Resolution | <0.00005ยฐC |
Typical stability | ยฑ0.002ยฐC/year |
Time constant | <0.1 |โfast, <1s standard |
Calibrated range | 20 / 50 / 100 / 200 / 500 / 1000dbar (plastic) 1000 / 2000 / 4000/ 6000/ 10000dbar (Ti) |
---|---|
Initial accuracy | ยฑ0.05% full scale |
Resolution | <0.001% full scale |
Typical Stability | ยฑ0.05% full scale / year |
Time constant | <10ms |
5s | 4 years, 25M samples |
---|---|
2Hz | 60 days, 10M samples |
16Hz | 30 days, 45M samples |
32Hz | 16days, 45M samples |